Horsch Startseite
Crop protection Hybrid farming

Error code 11


End position not reached

Warning at Maestro.

Maestro (11-2)

since version 9.65

When does the warning occur?

The valve for the half-width control has not reached end position.

Does a Drilling error (drilling drop-out) occur?

Yes!

What to do?

  • Check the functions of engine and sensor in the diagnostics.
  • Check the injector/Venturi area mechanically (e.g. light moving, blocked).

Is there an audible indication?

single audible signal

How is the warning confirmed?

not possible, until error has been rectified


Terms of use