Error code 110
Pressure sensor defect
Warning at Drill.Drill (110-1)
since version 10.05
When does the warning occur?
Wire break with <3.5mA, short-circuit with >21mA
Does a Drilling error (drilling drop-out) occur?
No.
What to do?
- Inspect cabling to sensor.
Is there an audible indication?
Single acoustic signal
How is the warning confirmed?
Not possible until error has been rectified