Middle not reached
Warning at Maestro.Maestro (12-2)
since version 9.65
When does the warning occur?
The valve for the half-width control has not reached middle position.
Does a Drilling error (drilling drop-out) occur?
Yes!
What to do?
- Check the functions of engine and sensor in the diagnostics.
- Check the injector/Venturi area mechanically (e.g. light moving, blocked).
Is there an audible indication?
single audible signal
How is the warning confirmed?
not possible, until error has been rectified
Terms of use
Note: The assistance operations given in the present application may only be carried out observing the safety notes in the operating instructions of the corresponding machine. Compensation claims for damages due to non-observance of the operating instructions are excluded.