Error code 134
Partner Slave not present
Alarm at Drill and Maestro.Drill (134-1)
since version 10.06
Maestro (134-2)
since version 10.06
When does the alarm occur?
Is there is a combination of HORSCH front- and rear attachments connected together via the ISOBUS,
functions one of the attachments as Master and one as Slave?
The attachment which functions as Slave is not identified.
functions one of the attachments as Master and one as Slave?
The attachment which functions as Slave is not identified.
Does a Drilling error (drilling drop-out) occur?
Yes!
What to do?
- Check the configuration for front and rear attachments.
- Inspect cabling.
- Restart Master JR after correcting the error (disconnect ISOBUS for 10 seconds and then reconnect). The slave is only recognised again after restarting the master.
Is there an audible indication?
3 successive acoustic signals
How is the alarm confirmed?
Press ESC to confirm
Terms of use
Note: The assistance operations given in the present application may only be carried out observing the safety notes in the operating instructions of the corresponding machine. Compensation claims for damages due to non-observance of the operating instructions are excluded.