Horsch Startseite
Crop protection Hybrid farming

Error code 162


Row module: Coulter pressure valve current too high

Warning at Drill and Maestro.

Drill (162-1)

Maestro (162-2)

since version 10.07

When does the warning occur?

* Current on coulter pressure valve too high: * Short-circuit (cable damaged). * Coulter pressure valve defective. * Module defective.

Does a Drilling error (drilling drop-out) occur?

No.

What to do?

  • Inspect cabling.
  • Check current on coulter pressure valve.
  • Replace coulter pressure valve if defective.
  • Replace module if defective.

Is there an audible indication?

Single acoustic signal

How is the warning confirmed?

Not possible until error has been rectified


Terms of use

Note: The assistance operations given in the present application may only be carried out observing the safety notes in the operating instructions of the corresponding machine. Compensation claims for damages due to non-observance of the operating instructions are excluded.