Error code 169
Row module: Fertiliser/seed flow sensor current too low
Warning at Drill and Maestro.Drill (169-1)
Maestro (169-2)
since version 10.07
When does the warning occur?
Current for fertiliser/seed flow sensor too low.
Cable break (cable damaged).
Fertiliser/seed flow sensor defective.
Module defective.
Cable break (cable damaged).
Fertiliser/seed flow sensor defective.
Module defective.
Does a Drilling error (drilling drop-out) occur?
No.
What to do?
- Inspect cabling.
- Check fertiliser/seed flow sensor.
- Restart system.
- Replace fertiliser/seed flow sensor if defective.
- Replace module if defective.
Is there an audible indication?
Single acoustic signal
How is the warning confirmed?
Not possible until error has been rectified
Terms of use
Note: The assistance operations given in the present application may only be carried out observing the safety notes in the operating instructions of the corresponding machine. Compensation claims for damages due to non-observance of the operating instructions are excluded.