Error code 185


Row module: Downpipe sensor undervoltage

Warning at Drill and Maestro.

Drill (185-1)

Maestro (185-2)

since version 10.07

When does the warning occur?

Supply voltage on downpipe sensor too low. Metering accuracy affected.

Does a Drilling error (drilling drop-out) occur?

No.

What to do?

  • Check the wiring.
  • Check supply voltage on downpipe sensor.
  • Replace downpipe sensor if defective.
  • A defective downpipe sensor can be deactivated in the machine control until replaced (see operating instructions).

Is there an audible indication?

Single acoustic signal

How is the warning confirmed?

Not possible until error has been rectified