Horsch Startseite
Crop protection Hybrid farming

Error code 198


Row module: Motor overload

Alarm at Drill and Maestro.

Drill (198-1)

Maestro (198-2)

since version 10.07

When does the alarm occur?

Torque of the motor too high for extended period.
Motor switches off.

Does a Drilling error (drilling drop-out) occur?

Yes!

What to do?

  • Check motor load.
  • Check metering unit for easy movement.
  • Check cotter pin, motor shaft as well as metering disc spacing according to operating instructions.
  • Acknowledge error message, motor will then restart.

Is there an audible indication?

3 successive acoustic signals

How is the alarm confirmed?

Press ESC to confirm


Terms of use