Error code 228
WorkLight Pro: Total current too high
Warning at Drill and Maestro.Drill (228-1)
since version 10.09
Maestro (228-2)
since version 10.09
When does the warning occur?
Total current consumption of the WorkLight Pro too high for an extended period (>25 A).
All headlight groups were switched off.
All headlight groups were switched off.
Does a Drilling error (drilling drop-out) occur?
No.
What to do?
- Observe max. WorkLight Pro total current (25 A).
- Switch off one headlight group and try again.
After what time is the warning repeated?
0 sec.
Is there an audible indication?
Single acoustic signal
How is the warning confirmed?
Not possible until error has been rectified
Terms of use