Error code 236
Row module: motor blocked
Alarm at Maestro.Maestro (236-2)
since version 10.10
When does the alarm occur?
Motor moves very sluggishly for a longer period or is blocked.
Does a Drilling error (drilling drop-out) occur?
Yes!
What to do?
- Check motor load.
- Check metering unit for easy movement.
- Check cotter pin, motor shaft as well as metering disc spacing according to operating instructions.
- Acknowledge error message, motor will then restart.
- Check row module ground connection.
Is there an audible indication?
3 successive acoustic signals
How is the alarm confirmed?
Press ESC to confirm