Error code 248


 

Basis Lib error

Alarm at Maistro, Drill and Maestro.

Maistro (248-3)

Drill (248-1)

Maestro (248-2)

When does the alarm occur?

* BasisLib error displayed on the terminal only in Beta software versions, e.g.: * IO voltage check at startup * Current checks * e.g.: 0x1E8 - Voltage or current problem * Additional hexadecimal code in the alarm indicates the exact error location of the software. This is required for a more exact analysis.

Does a Drilling error (drilling drop-out) occur?

No.

What to do?

  • Update machine to release version. The error is not displayed in release software versions.

  • Leave the machine de-energised for a longer period when restarting. e.g. 0x1E8 can occur if the machine has not yet been de-energised internally.
  • If error 0x1E8 occurs directly after a restart, it can be ignored.

  • Send a photo of the error to Horsch Service for precise analysis.

Is there an audible indication?

single acoustic signal

How is the alarm confirmed?

Press ESC to confirm