Error code 248
Basis Lib error
Alarm at Maistro, Drill and Maestro.Maistro (248-3)
Drill (248-1)
Maestro (248-2)
When does the alarm occur?
* BasisLib error displayed on the terminal only in Beta software versions, e.g.:
* IO voltage check at startup
* Current checks
* e.g.: 0x1E8 - Voltage or current problem
* Additional hexadecimal code in the alarm indicates the exact error location of the software. This is required for a more exact analysis.
Does a Drilling error (drilling drop-out) occur?
No.
What to do?
- Update machine to release version. The error is not displayed in release software versions.
- Leave the machine de-energised for a longer period when restarting. e.g. 0x1E8 can occur if the machine has not yet been de-energised internally.
- If error 0x1E8 occurs directly after a restart, it can be ignored.
- Send a photo of the error to Horsch Service for precise analysis.
Is there an audible indication?
single acoustic signal
How is the alarm confirmed?
Press ESC to confirm
Terms of use
Note: The assistance operations given in the present application may only be carried out observing the safety notes in the operating instructions of the corresponding machine. Compensation claims for damages due to non-observance of the operating instructions are excluded.