Error code 269
Checking row addressing: Connection between job computer and first row interrupted
Warning at Maestro.Maestro (269-2)
since version 10.12
When does the warning occur?
When checking row addressing it was detected that the connection between job computer and first connected row is interrupted.
Does a Drilling error (drilling drop-out) occur?
Yes!
What to do?
- Check wiring.
- Restart system.
- Inspect system for correct wiring and BUS errors.
After what time is the warning repeated?
0 sec.
Is there an audible indication?
Single acoustic signal
How is the warning confirmed?
not possible until error has been rectified
Terms of use