Horsch Startseite
Crop protection Hybrid farming

Error code 282


 

Row module: statistics cannot be updated

Warning at Maestro.

Maestro (282-2)

since version 10.16

When does the warning occur?

If implausible grains are detected by the row sensor, then these are not used for the statistics (missed/double seeds and coefficient of variation).
If the sensor reports implausible grains over a longer period of time (approx. 5 sec), the statistics cannot be recalculated (updated) and this error EC-282 is displayed.

Does a Drilling error (drilling drop-out) occur?

No.

What to do?

  • If the error occurs repeatedly on certain or individual rows, check the singulation settings in these rows (seed quality / under- or overpressure / sensor contamination / etc.)
  • If the error occurs uniformly across all rows, switch to one of the other row displays (quantity view or seed flow view). No reasonable detailed view can be calculated/displayed for the current seed parameters.

Is there an audible indication?

single audible signal

How is the warning confirmed?

not possible until the error has been rectified


Terms of use

Note: The assistance operations given in the present application may only be carried out observing the safety notes in the operating instructions of the corresponding machine. Compensation claims for damages due to non-observance of the operating instructions are excluded.

We use cookies to optimize and continuously improve our website for you. By continuing to use the website, you agree to the use of cookies. Further information on cookies can be found in our data protection declaration More