Error code 282
Row module: statistics cannot be updated
Warning at Maestro.Maestro (282-2)
since version 10.16
When does the warning occur?
If implausible grains are detected by the row sensor, then these are not used for the statistics (missed/double seeds and coefficient of variation).
If the sensor reports implausible grains over a longer period of time (approx. 5 sec), the statistics cannot be recalculated (updated) and this error EC-282 is displayed.
If the sensor reports implausible grains over a longer period of time (approx. 5 sec), the statistics cannot be recalculated (updated) and this error EC-282 is displayed.
Does a Drilling error (drilling drop-out) occur?
No.
What to do?
- If the error occurs repeatedly on certain or individual rows, check the singulation settings in these rows (seed quality / under- or overpressure / sensor contamination / etc.)
- If the error occurs uniformly across all rows, switch to one of the other row displays (quantity view or seed flow view). No reasonable detailed view can be calculated/displayed for the current seed parameters.
Is there an audible indication?
single audible signal
How is the warning confirmed?
not possible until the error has been rectified
Terms of use