Error code 283
Master job computer: Power voltage too low
Alarm at Maistro, Drill and Maestro.Maistro (283-3)
since version 10.17
Drill (283-1)
since version 10.17
Maestro (283-2)
since version 10.17
When does the alarm occur?
* Too low a power voltage was measured at the input of the subscriber master.
* Malfunction of the master and subsequent slaves or modules possible, as the master power voltage is forwarded to other slaves and modules depending on the type of wiring:
* Valves for e.g. folding are not actuated or are actuated with too little voltage
* Metering motors are not activated or have too little power.
Does a Drilling error (drilling drop-out) occur?
Yes!
What to do?
- Check the wiring.
- Check the Extrapower wiring if installed.
- Check supply voltage.
- Optimal operating range 11–16 V on master input.
Is there an audible indication?
single audible signal
How is the alarm confirmed?
Press ESC to confirm