Horsch Startseite
Crop protection Hybrid farming

Error code 283


 

Master job computer: Power voltage too low

Alarm at Maistro, Drill and Maestro.

Maistro (283-3)

since version 10.17

Drill (283-1)

since version 10.17

Maestro (283-2)

since version 10.17

When does the alarm occur?

* Too low a power voltage was measured at the input of the subscriber master. * Malfunction of the master and subsequent slaves or modules possible, as the master power voltage is forwarded to other slaves and modules depending on the type of wiring: * Valves for e.g. folding are not actuated or are actuated with too little voltage * Metering motors are not activated or have too little power.

Does a Drilling error (drilling drop-out) occur?

Yes!

What to do?

  • Check the wiring.
  • Check the Extrapower wiring if installed.
  • Check supply voltage.
  • Optimal operating range 11–16 V on master input.

Is there an audible indication?

single audible signal

How is the alarm confirmed?

Press ESC to confirm


Terms of use

Note: The assistance operations given in the present application may only be carried out observing the safety notes in the operating instructions of the corresponding machine. Compensation claims for damages due to non-observance of the operating instructions are excluded.

We use cookies to optimize and continuously improve our website for you. By continuing to use the website, you agree to the use of cookies. Further information on cookies can be found in our data protection declaration More