Error code 300
Weighing module: Power voltage too low
Warning at Maestro.Maestro (300-2)
since version 10.18
When does the warning occur?
Power voltage too low.
Does a Drilling error (drilling drop-out) occur?
No.
What to do?
- Check power supply on module. Optimal operating range 10-16 V.
- Check tractor supply.
- Check wiring to module (power supply via job computer (Isobus) or separate cable).
Is there an audible indication?
single audible signal
How is the warning confirmed?
not possible until the error has been rectified