Error code 333


 

AutoLine: Settings TC incompatible!

Alarm at Maistro, Drill and Maestro.

Maistro (333-3)

since version 10.18

Drill (333-1)

since version 10.18

Maestro (333-2)

since version 10.18

When does the alarm occur?

The connected terminal cannot support the current Tramline/AutoLine settings as it only reports Tramline Control Level 1.


=> A tramlines rhythm with half a working width at the start of the field must not be set. This would be a function of Tramline Control Level 2.

Does a Drilling error (drilling drop-out) occur?

Yes!

What to do?

  • Check AutoLine/Tramline settings in our AutoLine screen:
    • If AutoLine/Tramline Control is to be used with this terminal, then select tramline rhythm without half working width offset.
    • Use terminal with at least Tramline Control Level 2. E.g. Horsch Touch 800/1200 or Horsch eos T10 or similar.

Is there an audible indication?

3 successive acoustic signals

How is the alarm confirmed?

Press ESC to confirm