Error code 43


 

Liquid fertiliser zero

Alarm at Drill and Maestro.

Drill (43-1)

since version 9.67
Show older versions

Maestro (43-2)

since version 9.67
Show older versions

When does the alarm occur?

Quantity "0", if the flow meter does not measure a pulse within 3 seconds.

Does a Drilling error (drilling drop-out) occur?

No.

What to do?

  • Check the hopper contents.
  • Check the tap position.
  • Check the system for leaks or blockage.
  • Check pulse counting in the diagnostics.

After what time is the alarm repeated?

3 sec.

Is there an audible indication?

single audible signal

How is the alarm confirmed?

Press ESC to confirm.