Error code 60
Row computer speed too high
Alarm at Maestro.Maestro (60-2)
since version 9.67
When does the alarm occur?
The advancing speed is too high. The metering motor is unable to maintain the demanded rotary speed. The nominal plant distance can thus not be maintained.
Does a Drilling error (drilling drop-out) occur?
No.
What to do?
- Reduce the travel speed.
How is the alarm confirmed?
Not possible until error has been rectified
Terms of use
Note: The assistance operations given in the present application may only be carried out observing the safety notes in the operating instructions of the corresponding machine. Compensation claims for damages due to non-observance of the operating instructions are excluded.