Error code | Machine assignment | Type | Error text |
Screenshots
Software version |
Repetition time | Confirmation | Occurrence | Instruction for action | Audible warning in case of occurrence | Critical problem |
---|---|---|---|---|---|---|---|---|---|---|
1
|
|
W | Fan speed x fallen short of |
Drill
–
since version 9.65
Maestro
–
since version 9.65
|
not possible, until error has been rectified |
Fan speed too low. Limiting values for fan speed, which leads to an error message, can be configured. Compliance with the set values is not possible. |
|
single audible signal | Drilling error (drilling drop-out): Yes! | |
2
|
|
A | Fan speed x fallen short of |
Drill
–
since version 9.67
Drill
–
since version 9.67
Drill
–
Versions 9.65 and 9.66
Maestro
–
since version 9.67
Maestro
–
since version 9.67
Maestro
–
since version 9.67
Maestro
–
Versions 9.65 and 9.66
|
15 sec. | Not necessary! Goes away automatically after 5 sec. The associated warning will remain . |
Fan speed too low. Limiting values for fan speed, which leads to an error message, can be configured. Compliance with the set values is not possible. |
|
3 successive audible signals | Drilling error (drilling drop-out): Yes! |
3
|
|
W | Fan speed x exceeded |
Drill
–
since version 9.65
Maestro
–
since version 9.65
|
not possible, until error has been rectified | Limiting values, which lead to the error message, can be configured. Compliance with the set values is not possible. (no subsequent alarm) |
|
single audible signal | Drilling error (drilling drop-out): No. | |
4
|
|
W | Nominal values cannot be met (too low) |
Drill
–
since version 9.65
Drill
–
since version 9.65
Maestro
–
since version 9.65
Maestro
–
since version 9.65
Maestro
–
since version 9.65
|
not possible, until error has been rectified | Occurs as soon as the quantity cannot be met. Applies for row computers and metering equipment (seed, solid and liquid fertiliser). |
|
single audible signal for each row computer affected | Drilling error (drilling drop-out): No. | |
5
|
|
W | Nominal values cannot be met (too high) |
Drill
–
since version 9.65
Drill
–
since version 9.65
Maestro
–
since version 9.65
Maestro
–
since version 9.65
Maestro
–
since version 9.65
|
not possible, until error has been rectified | Occurs as soon as the quantity cannot be met. Applies for row computers and metering equipment (seed, solid and liquid fertiliser). |
|
single audible signal for each row computer affected | Drilling error (drilling drop-out): No. | |
6
|
|
W | Vacuum too low |
Maestro
–
since version 9.65
|
not possible, until error has been rectified | The set vacuum cannot be complied with. Limiting value depending on fruit parameter |
|
single audible signal | Drilling error (drilling drop-out): Yes! | |
7
|
|
W | Vacuum too high |
Maestro
–
since version 9.65
|
not possible, until error has been rectified | The set vacuum cannot be complied with. Limiting value depending on fruit parameter. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
8
|
|
W | ISOBUS error |
Drill
–
since version 9.65
Maestro
–
since version 9.65
|
not possible, until error has been rectified | Communication between ISOBUS system and master job computers affected. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
9
|
|
W | ECU-BUS error |
Drill
–
since version 9.65
Maestro
–
since version 9.65
|
not possible, until error has been rectified | Communication between master-computer "CAN-OUT" and the connected components is impaired. |
|
continuous lined-up audible signals | Drilling error (drilling drop-out): No. | |
10
|
|
W | ECU2-BUS error |
Maestro
–
since version 9.65
|
not possible, until error has been rectified | Communication between slave-computer "CAN-OUT" and the connected components is impaired. |
|
continuous lined-up audible signals | Drilling error (drilling drop-out): No. | |
11
|
|
W | End position not reached |
Maestro
–
since version 9.65
|
not possible, until error has been rectified | The valve for the half-width control has not reached end position. |
|
single audible signal | Drilling error (drilling drop-out): Yes! | |
12
|
|
W | Middle not reached |
Maestro
–
since version 9.65
|
not possible, until error has been rectified | The valve for the half-width control has not reached middle position. |
|
single audible signal | Drilling error (drilling drop-out): Yes! | |
13
|
|
W | Seed/fertiliser flow in the tram line |
Drill
–
since version 9.65
|
not possible, until error has been rectified |
"Agtron", "DickeyJ" or "HORSCH" has been selected as seed/fertiliser flow monitoring system. Seed/fertiliser flow is indicated in the seed hoses of the tram line during operation. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
14
|
|
W | No seed/fertiliser flow |
Drill
–
since version 9.65
|
not possible, until error has been rectified |
"Agtron" has been selected as seed/fertiliser flow monitoring system. No seed/fertiliser flow indicated during working position. |
|
single audible signal | Drilling error (drilling drop-out): Yes! | |
15
|
|
W | Seed/fertiliser flow in the tram line |
Maestro
–
since version 9.65
|
not possible, until error has been rectified |
"Dickey John" has been selected as seed/fertiliser flow monitoring system. Seed/fertiliser flow is indicated in the tram line. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
16
|
|
W | No seed/fertiliser flow |
Maestro
–
since version 9.65
|
not possible, until error has been rectified |
"Dickey John" has been selected as seed/fertiliser flow monitoring system. In working position no seed/fertiliser flow is indicated in the corresponding circle for the affected sensors. |
|
single audible signal | Drilling error (drilling drop-out): Yes! | |
17
|
|
W | Seed/fertiliser flow: Communication error (yellow) |
Maestro
–
since version 9.65
|
not possible, until error has been rectified |
"Dickey John" has been selected as seed/fertiliser flow monitoring system. The communication between two successive sensors is interrupted from one side of the circuit (Loop) to the displayed sensors. System is still fully functional. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
18
|
|
W | Seed/fertiliser flow: Communication error (red) |
Maestro
–
since version 9.65
|
not possible, until error has been rectified |
"Dickey John" has been selected as seed-fertiliser flow monitoring system. The communication between the sensors is interrupted from two sides in the circle (Loop). Correct seed/fertiliser flow monitoring cannot be ensured. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
19
|
|
W |
Row computer over-current (current consumption too high) |
Maestro
–
since version 9.65
|
not possible, until error has been rectified | Current consumption for the displayed row too high. Pre-set limiting value: 4 A per row computer. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
20
|
|
W |
Variation coefficient (VC) row computer (too high) |
Maestro
–
since version 9.65
|
not possible, until error has been rectified | Variation coefficient (VC) too high. The VC is shown separately for each row computer. For the fruit parameters the limiting value can be adjusted. The pre-set value depends on the fruit type. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
21
|
|
A | Motor x stopped! |
Drill
–
since version 9.67
Drill
–
since version 9.67
Drill
–
since version 9.67
Drill
–
Versions 9.65 and 9.66
Maestro
–
since version 9.67
Maestro
–
since version 9.67
Maestro
–
since version 9.67
Maestro
–
Versions 9.65 and 9.66
|
0 sec. | not possible, until error has been rectified | The gear motor for fertiliser/seed metering for the indicated hopper is stopped during work. |
|
3 successive audible signals | Drilling error (drilling drop-out): Yes! |
22
|
|
A | Restart during work |
Drill
–
since version 9.67
Drill
–
Versions 9.65 and 9.66
|
0 sec. | Press ESC to confirm. | Restarting of terminal during a work process. |
|
3 successive audible signals | Drilling error (drilling drop-out): Yes! |
23
|
|
A | 2. Machine computer failed |
Drill
–
since version 9.67
Drill
–
Versions 9.65 and 9.66
Maestro
–
since version 9.67
Maestro
–
Versions 9.65 and 9.66
|
60 sec. | Press ESC to confirm. | Interruption of connection to the displayed slave computer. |
|
single audible signal | Drilling error (drilling drop-out): Yes! |
24
|
|
A | Row computer has failed |
Maestro
–
since version 9.67
Maestro
–
Versions 9.65 and 9.66
|
10 sec. | Press ESC to confirm. | Connection to the indicated row computer interrupted. Frequently caused by missing power supply for the indicated row. However, it may also be caused by a electronics defect in the indicated row. |
|
3 successive audible signals | Drilling error (drilling drop-out): Yes! |
25
|
|
A | Row computer motor overloaded |
Maestro
–
since version 9.67
Maestro
–
Versions 9.65 and 9.66
|
when drilling 60 sec., otherwise 60 sec. | Press ESC to confirm. | Drive motor in the indicated row reports too high current consumption (permanently higher than 5 ampere). Current consumption limited by engine speed reduction. |
|
single audible signal | Drilling error (drilling drop-out): No. |
26
|
|
A | Row computer: Motor defective |
Maestro
–
since version 9.67
Maestro
–
Versions 9.65 and 9.66
|
when drilling 60 sec., otherwise 60 sec. | Press ESC to confirm. | Drive motor in the indicated row reports "defect". |
|
3 successive audible signals | Drilling error (drilling drop-out): Yes! |
27
|
|
A | Row computer: Motor overheating |
Maestro
–
since version 9.67
Maestro
–
Versions 9.65 and 9.66
|
when drilling 10 sec., otherwise 60 sec. | Press ESC to confirm. | Drive motor in the indicated row reports "too high temperature". Motor switches off. |
|
3 successive audible signals | Drilling error (drilling drop-out): Yes! |
28
|
|
W | Row computer: electric voltage too low (supply voltage) |
Maestro
–
since version 9.65
|
not possible, until error has been rectified |
The measured voltage on the drive motor of the indicated row is too low. This is frequently caused by a voltage drop in the system, e.g. - caused by a too high power consumption of the upstream drive motors or -by a faulty electric connection to the supply source |
|
single audible signal | Drilling error (drilling drop-out): No. | |
29
|
|
A | Row computer: Metering unit blocked |
Maestro
–
since version 9.67
Maestro
–
Versions 9.65 and 9.66
|
Press ESC to confirm. | Metering disc in the indicated row jammed could not b release by turning back. |
|
single audible signal | Drilling error (drilling drop-out): Yes! | |
30
|
|
A | Overflow of grains (overflow alarm) |
Maestro
–
since version 9.67
Maestro
–
Versions 9.65 and 9.66
|
0 sec. | Press ESC to confirm. |
The overflow indicates, that far to many grains are metered. The display of this warning can be configured, depending on the type of fruit. Presetting: Warning message is only activated for certain crops (software version dependent). In 10.16, for example, the warning message is activated for "Sugar beet", "Sunflowers" and "Canola" and deactivated for all other crop types. For standard Maestro machine types (Maestro CC/SW/RC, the error is an alarm). For the new Maestros (X and V generation), the error is a warning. |
|
3 successive audible signals | Drilling error (drilling drop-out): No. |
31
|
|
W | Metering motor speed warning (speed too high) |
Drill
–
since version 9.65
Maestro
–
since version 9.65
|
not possible, until error has been rectified | Speed of fertiliser / seed metering unit too high. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
32
|
|
A | Rotation speed too high |
Drill
–
since version 9.67
Drill
–
since version 9.67
Drill
–
since version 9.67
Drill
–
Versions 9.65 and 9.66
Maestro
–
since version 9.67
Maestro
–
since version 9.67
Maestro
–
since version 9.67
Maestro
–
Versions 9.65 and 9.66
|
5 sec. | not possible, until error has been rectified | Fertiliser/seed metering unit: Maximum speed exceeded. |
|
single audible signal | Drilling error (drilling drop-out): No. |
33
|
|
W | Speed too low |
Drill
–
since version 9.65
Maestro
–
since version 9.65
|
not possible, until error has been rectified | Fertiliser/seed metering unit: Minimum speed fallen short of. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
34
|
|
W | Total current consumption near maximum |
Drill
–
since version 9.65
Maestro
–
since version 9.65
|
not possible, until error has been rectified |
Warning limits: 45 A single computer system 90 A two computer system Value must be exceeded for 3 seconds without interruption, before the warning is displayed. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
35
|
|
A | Seed/fertiliser flow: Module failed |
Drill
–
since version 9.67
Drill
–
Versions 9.65 and 9.66
|
If module fails again after activation. | Press ESC to confirm |
"Dickey John" has been selected as seed/fertiliser flow monitoring system. The connection to the seed/fertiliser flow modulel is interrupted. |
|
3 successive audible signals | Drilling error (drilling drop-out): No. |
36
|
|
A | Sporadic interruption of work |
Drill
–
since version 9.67
Drill
–
Versions 9.65 and 9.66
Maestro
–
since version 9.67
Maestro
–
Versions 9.65 and 9.66
|
Press ESC to confirm. | Occurs, when the work signal at a speed of > 3 km/h,is interrupted longer than 3 seconds. |
|
single audible signal | Drilling error (drilling drop-out): Yes! | |
37
|
|
A | Value outside input range |
Drill
–
since version 9.67
Drill
–
Versions 9.65 and 9.66
Maestro
–
since version 9.67
Maestro
–
Versions 9.65 and 9.66
|
After another input outside the input range. | not necessary | Occurs as soon as the chosen input range is not permitted. The impermissibly entered value will not be accepted. |
|
3 successive audible signals | Drilling error (drilling drop-out): No. |
38
|
|
W | Pressure loss in the indicated tank |
Drill
–
since version 9.65
Maestro
–
since version 9.65
|
not possible, until error has been rectified | Always takes place when a pressure loss/switching signal is available (depending on the fan). |
|
single audible signal | Drilling error (drilling drop-out): Yes! | |
39
|
|
A | Pressure loss in the indicated tank |
Drill
–
since version 9.67
Drill
–
since version 9.67
Drill
–
Versions 9.65 and 9.66
Maestro
–
since version 9.67
Maestro
–
Versions 9.65 and 9.66
|
10 sec. | Press ESC to confirm. | Only occurs in work position, when the pressure loss/switching signal is applied for >5 seconds without interruption. |
|
3 successive audible signals | Drilling error (drilling drop-out): Yes! |
40
|
|
A | Rotary speed of left hand rotary cross harrow too low |
Drill
–
since version 9.67
Drill
–
Versions 9.65 and 9.66
|
10 sec. | Press ESC to confirm. | Monitoring the rotary cross harrows: Rotation speed left |
|
3 successive audible signals | Drilling error (drilling drop-out): No. |
41
|
|
A | Rotary speed of right hand rotary cross harrow too low |
Drill
–
since version 9.67
Drill
–
Versions 9.65 and 9.66
|
10 sec. | Press ESC to confirm. | Monitoring the rotary cross harrows: Rotation speed right |
|
3 successive audible signals | Drilling error (drilling drop-out): No. |
42
|
|
A | Zero grain alarm |
Maestro
–
since version 9.67
Maestro
–
Versions 9.65 and 9.66
|
3 sec. | Press ESC to confirm. |
Occurs when the downpipe sensor does not indicate any grains. (When starting after 4 sec., and during work after 3 sec.) |
|
single audible signal | Drilling error (drilling drop-out): Yes! |
43
|
|
A | Liquid fertiliser zero |
Drill
–
since version 9.67
Drill
–
Versions 9.65 and 9.66
Maestro
–
since version 9.67
Maestro
–
Versions 9.65 and 9.66
|
3 sec. | Press ESC to confirm. | Quantity "0", if the flow meter does not measure a pulse within 3 seconds. |
|
single audible signal | Drilling error (drilling drop-out): No. |
44
|
|
W | Filling level low (hopper empty) |
Drill
–
since version 9.65
Maestro
–
since version 9.67
Maestro
–
Versions 9.65 and 9.66
|
not possible, until error has been rectified | Filling level message as soon as the tank filling level sensor is unable to indicate any seed/fertiliser. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
45
|
|
A | Seed bridging alarm |
Drill
–
since version 9.67
Drill
–
since version 9.67
Drill
–
since version 9.67
Drill
–
Versions 9.65 and 9.66
Maestro
–
since version 9.67
Maestro
–
since version 9.67
Maestro
–
Versions 9.65 and 9.66
|
Repetition after changing the working position. | Press ESC to confirm. | Metering unit for the displayed hopper is empty. |
|
3 successive audible signals | Drilling error (drilling drop-out): Yes! |
47
|
|
W | Row motor switched on |
Maestro
–
since version 9.67
Maestro
–
Versions 9.65 and 9.66
|
not possible, until error has been rectified | One of the row drives is manually switched on. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
49
|
|
A | Half-width flap: End position not reached |
Drill
–
since version 9.67
Drill
–
Versions 9.65 and 9.66
|
The valve for the half-width control has not reached the end position. |
|
3 successive audible signals | Drilling error (drilling drop-out): Yes! | ||
50
|
|
A | Half-width flap: Middle not reached |
Drill
–
since version 9.67
Drill
–
Versions 9.65 and 9.66
Maestro
–
since version 9.67
Maestro
–
Versions 9.65 and 9.66
|
The valve for the half-width control has not reached the end position. |
|
3 successive audible signals | Drilling error (drilling drop-out): Yes! | ||
51
|
|
A | "Agtron" system error | Agtronmodul reports a system error |
|
Drilling error (drilling drop-out): No. | ||||
52
|
|
W | Metering motor x overheating | Overheating in the electric circuit. |
|
Drilling error (drilling drop-out): No. | ||||
53
|
|
W | Metering motor x overloaded |
Drill
–
since version 9.66
Drill
–
since version 9.66
Maestro
–
since version 9.65
Maestro
–
since version 9.65
|
Press ESC to confirm | Is displayed as soon as the current of the displayed metering motor is higher than 12 A. |
|
Drilling error (drilling drop-out): Yes! | ||
54
|
|
W | Metering motor x current too high |
Drill
–
since version 9.66
Drill
–
since version 9.66
Maestro
–
since version 9.65
Maestro
–
since version 9.65
|
10 sec. | Press ESC to confirm | Is displayed as soon as the current measured over the last minute is higher than 9 A. |
|
Drilling error (drilling drop-out): No. | |
56
|
|
A | Seed/fertiliser flow: Module, voltage too low |
Drill
–
since version 9.67
Drill
–
Versions 9.65 and 9.66
Maestro
–
since version 9.67
Maestro
–
Versions 9.65 and 9.66
|
60 sec. | Press ESC to confirm | Current measured at the seed/fertiliser monitoring module too low. |
|
single audible signal | Drilling error (drilling drop-out): No. |
57
|
|
A | Seed/fertiliser flow: Module, voltage too high |
Drill
–
since version 9.67
Drill
–
Versions 9.65 and 9.66
Maestro
–
since version 9.67
Maestro
–
Versions 9.65 and 9.66
|
60 sec. | Press ESC to confirm | Current measured at the seed/fertiliser monitoring module too high. |
|
single audible signal | Drilling error (drilling drop-out): No. |
60
|
|
A | Row computer speed too high |
Maestro
–
since version 9.67
Maestro
–
Versions 9.65 and 9.66
|
Not possible until error has been rectified | The advancing speed is too high. The metering motor is unable to maintain the demanded rotary speed. The nominal plant distance can thus not be maintained. |
|
Drilling error (drilling drop-out): No. | ||
64
|
|
W | Overheating LED illumination |
Drill
–
since version 10.13
Drill
–
Versions 9.66 to 10.12
Maestro
–
since version 10.13
Maestro
–
Versions 9.66 to 10.12
|
not possible, until error has been rectified |
Lighting module has reached its temperature limit. The illumination switches off automatically to avoid damage caused by overheating. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
65
|
|
A | Fertiliser flow module failed |
Maestro
–
since version 9.67
Maestro
–
only version 9.66
|
60 sec. | Press ESC to confirm | The connection to the fertiliser flow module is interrupted. |
|
Drilling error (drilling drop-out): No. | |
66
|
|
A | Check folding direction |
Drill
–
since version 9.67
Maestro
–
since version 9.67
|
Press ESC to confirm. | Hydraulic control unit operated to the wrong direction. |
|
Drilling error (drilling drop-out): No. | ||
67
|
|
A | Folding computer failed |
Drill
–
since version 9.67
|
60 sec. | Press ESC to confirm. | The connection to the fertiliser flow module is interrupted. |
|
3 successive audible signals | Drilling error (drilling drop-out): No. |
68
|
|
A |
Micro-granular compound computer failed AutoForce computer failed Drilling depth computer failed |
Maestro
–
since version 9.67
|
60 sec. | Press ESC to confirm. | Connection to slave job computer (Slave extension) is disrupted. |
|
3 successive audible signals | Drilling error (drilling drop-out): No. |
69
|
|
A | Differences in wing inclinations |
Drill
–
since version 9.67
|
3 sec. | Press ESC to confirm. |
Permissible deviation from the folding wing inclination exceeded. Automatic folding cannot be continued. Danger of the machine tipping over. |
|
3 successive audible signals | Drilling error (drilling drop-out): No. |
70
|
|
W | Powerpack speed too low |
Drill
–
since version 10.03
Maestro
–
since version 9.67
|
not possible, until error has been rectified | Rotary speed outside the permissible range. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
71
|
|
W | Powerpack speed too high! |
Drill
–
since version 10.03
Maestro
–
since version 9.67
|
not possible, until error has been rectified | Rotary speed outside the permissible range. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
72
|
|
W | Inclination sensor defective | not possible, until error has been rectified |
Values outside the permissible range are measured at the sensor input Unable to activate the folding function. |
|
single audible signal | Drilling error (drilling drop-out): No. | ||
73
|
|
W | Inclination sensor defective |
Drill
–
since version 9.68
|
Not possible until error has been rectified |
Values outside the permissible range are measured at the sensor input Unable to activate the folding function. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
74
|
|
A | Seed/fertiliser flow: Module x failed |
Drill
–
since version 10.03
|
60 sec. | Press ESC to confirm |
"HORSCH" has been selected as seed/fertiliser flow monitoring system. The connection to the seed/fertiliser flow module is interrupted. |
|
3 successive audible signals | Drilling error (drilling drop-out): No. |
75
|
|
A | Row not drilling |
Maestro
–
since version 9.68
|
3 seconds | not possible, until error has been rectified |
A certain rotational speed of the single grain metering unit is expected. However, the single grain metering unit does not turn. |
|
3 successive audible signals | Drilling error (drilling drop-out): Yes! |
76
|
|
W | No seed/fertiliser flow |
Drill
–
since version 10.03
|
Not possible until error has been rectified |
"HORSCH" has been selected as seed/fertiliser flow monitoring system. No seed/fertiliser flow indicated during working position. |
|
single audible signal | Drilling error (drilling drop-out): Yes! | |
79
|
|
W | Seed/fertiliser flow in the tram line |
Drill
–
since version 10.03
|
Press ESC to confirm | "HORSCH" has been selected as seed/fertiliser flow monitoring system. Seed/fertiliser flow is indicated in the tram line. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
80
|
|
A | No seed/fertiliser flow |
Drill
–
since version 10.03
|
10 sec. | Press ESC to confirm | "HORSCH" has been selected as seed/fertiliser flow monitoring system. No seed/fertiliser flow is indicated on sensor x in row x. |
|
3 successive audible signals | Drilling error (drilling drop-out): Yes! |
83
|
|
W | Load cell x not found |
Maestro
–
since version 10.02
|
Not possible until error has been rectified | Communication to the load cell interrupted. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
84
|
|
W | External control terminal not found |
Maestro
–
since version 10.02
|
Not possible until error has been rectified | Communication to the external control terminal interrupted. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
85
|
|
W | Load cell error |
Maestro
–
since version 10.02
|
Not possible until error has been rectified |
An error is signalled by the load cell. There are different causes for the error message occurring (temperature; mechanical deformation,...). |
|
single audible signal | Drilling error (drilling drop-out): No. | |
86
|
|
W | External control terminal fault |
Maestro
–
since version 10.02
|
Not possible until error has been rectified |
An error is signalled by the external control terminal. There are different causes for the error message occurring. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
87
|
|
W | AutoForce: Sensor cable break |
Maestro
–
since version 10.05
|
Not possible until error has been rectified | The sensor provides a value lower than 2 mA. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
88
|
|
W | AutoForce: Sensor short-circuit |
Maestro
–
since version 10.05
|
Not possible until error has been rectified | The sensor provides a value larger than 22mA |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
89
|
|
W | Row module: BUS overload |
Drill
–
since version 10.05
Maestro
–
since version 10.05
|
Not possible until error has been rectified | The CAN BUS module has a too high frequency. (BUS error) |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
90
|
|
W | Row module: Electronics voltage low |
Drill
–
since version 10.05
Maestro
–
since version 10.05
|
Not possible until error has been rectified | Electronic voltage too low. Module still operational. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
91
|
|
W | Row module: Excess voltage |
Drill
–
since version 10.05
Maestro
–
since version 10.05
|
Not possible until error has been rectified | Electronic voltage too high. Module still operational. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
92
|
|
W | Row module: Parameter reset to factory settings |
Drill
–
since version 10.05
Maestro
–
since version 10.05
|
Not possible until error has been rectified |
All module parameters were reset to factory settings. Occurrence is possible after update as long as Service Tool is connected. Error must not be displayed anymore after restarting the machine. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
93
|
|
A | Row module: Communication error (Slave communication time-out) |
Drill
–
since version 10.05
Maestro
–
since version 10.05
|
3 seconds | Press ESC to confirm |
Power supply to module is not present or too low. Motor processor has corrupted or no software. |
|
3 successive acoustic signals | Drilling error (drilling drop-out): Yes! |
95
|
|
W | Row module: Watchdog error |
Drill
–
since version 10.05
Maestro
–
since version 10.05
|
Not possible until error has been rectified | Internal software error. |
|
Single acoustic signal | Drilling error (drilling drop-out): Yes! | |
96
|
|
W | Row module: Parameter limits |
Drill
–
since version 10.05
Maestro
–
since version 10.05
|
Not possible until error has been rectified | Parameter set outside permissible parameter limit. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
98
|
|
W | Row module: Target speed cannot be retained |
Drill
–
since version 10.06
Maestro
–
since version 10.05
|
3 seconds | Alarm Maestro: confirm with ESC Warning message seed drill: not possible until error is remedied |
Specified target speed for the metering motor cannot be achieved. |
|
3 successive acoustic signals | Drilling error (drilling drop-out): Yes! |
99
|
|
A | Row module: Motor excess current |
Drill
–
since version 10.06
Drill
–
only version 10.05
Maestro
–
since version 10.05
|
3 seconds | Press ESC to confirm | Motor will be shut off and remains stationary. Motor constantly heavily overload for a certain time period. |
|
3 successive acoustic signals | Drilling error (drilling drop-out): Yes! |
100
|
|
A | Row module: Wire break (motor) |
Drill
–
since version 10.05
Maestro
–
since version 10.05
|
3 seconds | Press ESC to confirm | Connection between module and motor interrupted. |
|
3 successive acoustic signals | Drilling error (drilling drop-out): Yes! |
101
|
|
A | Row module: Overload (motor) |
Drill
–
since version 10.06
Drill
–
only version 10.05
Maestro
–
since version 10.05
|
3 seconds | Press ESC to confirm | Motor overloaded. Motor shuts off and stops. |
|
3 successive acoustic signals | Drilling error (drilling drop-out): Yes! |
102
|
|
A | Seeder row module: Short-circuit (motor) |
Drill
–
since version 10.05
Maestro
–
since version 10.05
|
3 seconds | Press ESC to confirm | One or several phases of the motor have short circuited. |
|
3 successive acoustic signals | Drilling error (drilling drop-out): Yes! |
103
|
|
W | Row module: Duplicate addressing |
Drill
–
since version 10.05
Maestro
–
since version 10.05
|
Not possible until error has been rectified | Two or more modules have the same address. |
|
Single acoustic signal | Drilling error (drilling drop-out): Yes! | |
104
|
|
A | Row module: Communication error (Slave communication time-out) |
Drill
–
since version 10.05
Maestro
–
since version 10.05
|
3 seconds | Press ESC to confirm | No communication with seeder row module for at least 5 seconds. |
|
3 successive acoustic signals | Drilling error (drilling drop-out): Yes! |
105
|
|
W | Row module: Power voltage low |
Drill
–
since version 10.05
Maestro
–
since version 10.05
|
Not possible until error has been rectified | Power voltage too low. Motor rpm limited. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
106
|
|
W | Row module: Power voltage too high |
Drill
–
since version 10.05
Maestro
–
since version 10.05
|
Not possible until error has been rectified | Power voltage too high. Module still operational. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
107
|
|
A | Row module: Electronics voltage to low |
Drill
–
since version 10.05
Maestro
–
since version 10.05
|
3 seconds | Press ESC to confirm | Electronic voltage too low, motor will be shuts off and remains stationary. |
|
3 successive acoustic signals | Drilling error (drilling drop-out): Yes! |
108
|
|
A | Row module: Power voltage too low |
Drill
–
since version 10.05
Maestro
–
since version 10.05
|
3 seconds | Press ESC to confirm | Power voltage too low. Motor shuts off and stops. |
|
3 successive acoustic signals | Drilling error (drilling drop-out): Yes! |
109
|
|
A | Inspect flap device |
Drill
–
since version 10.05
|
Press ESC to confirm |
Inspection executed for Pronto 12SW 3m EU. Pressure difference in the hydraulics, control device was actuated in the false direction. |
|
3 successive acoustic signals | Drilling error (drilling drop-out): No. | |
110
|
|
W | Pressure sensor defect |
Drill
–
since version 10.05
|
Not possible until error has been rectified | Wire break with <3.5mA, short-circuit with >21mA |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
111
|
|
W | Pressure sensor defect |
Drill
–
since version 10.05
|
Not possible until error has been rectified | Wire break with <3.5mA, short-circuit with >21mA |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
112
|
|
A | Metering motor overload |
Drill
–
since version 10.05
Maestro
–
since version 10.05
|
Press ESC to confirm |
Metering motor overloaded. Current consumption exceeds the set limiting value. Mean value of metering unit over 60 seconds above 12A or mean value over 5 seconds above 15A. |
|
3 successive acoustic signals | Drilling error (drilling drop-out): Yes! | |
113
|
|
W | Row module: Transfer parameter |
Drill
–
since version 10.05
Maestro
–
since version 10.06
|
Not possible until error has been rectified |
Parameter not transferred correctly. The job computer software does not match the row module software. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
114
|
|
W | Row module: Minimum speed for metering unit undershot |
Drill
–
since version 10.05
Maestro
–
since version 10.05
|
Not possible until error has been rectified | When the minimum speed for the metering unit is constantly undershot (will be indicated by the fruit parameter mask). |
|
Single acoustic signal | Drilling error (drilling drop-out): Yes! | |
115
|
|
W | Row module: Maximum speed for metering unit exceeded |
Drill
–
since version 10.05
Maestro
–
since version 10.05
|
Not possible until error has been rectified | When the maximum speed for the metering unit is constantly exceeded (will be indicated by the fruit parameter mask). |
|
Single acoustic signal | Drilling error (drilling drop-out): Yes! | |
116
|
|
W | Row module: Short-circuit or motor driver temperature |
Drill
–
since version 10.05
Maestro
–
since version 10.05
|
Not possible until error has been rectified | Short-circuit on the motor cable or power driver from the module is too warm. |
|
Single acoustic signal | Drilling error (drilling drop-out): Yes! | |
117
|
|
W | Row module: Motor driver voltage |
Drill
–
since version 10.05
Maestro
–
since version 10.05
|
Not possible until error has been rectified | Undervoltage on power drive. |
|
Single acoustic signal | Drilling error (drilling drop-out): Yes! | |
118
|
|
A | Row module: Motor reset |
Drill
–
since version 10.06
Maestro
–
since version 10.05
|
3 sec. | Press ESC to confirm | Motor controller restarts unexpectedly. |
|
3 successive acoustic signals | Drilling error (drilling drop-out): Yes! |
119
|
|
W | Row module: Sensor time-out |
Drill
–
since version 10.05
Maestro
–
since version 10.05
|
Not possible until error has been rectified | Communication from module to sensor failed. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
120
|
|
W | Row module: Sensor defective |
Drill
–
since version 10.05
Maestro
–
since version 10.05
|
Not possible until error has been rectified |
Sensor defective. Sensor connection disrupted. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
121
|
|
W | Row module: Sensor undervoltage |
Drill
–
since version 10.05
Maestro
–
since version 10.05
|
Not possible until error has been rectified | Operation voltage on sensor too low. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
122
|
|
W | Row module: Sensor LIN communication faulty |
Drill
–
since version 10.05
Maestro
–
since version 10.05
|
Not possible until error has been rectified | Incorrect messages are sent to sensor. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
123
|
|
W | Row module: Metering unit motor speed too low |
Drill
–
since version 10.05
Maestro
–
since version 10.05
|
Not possible until error has been rectified | Engine speed too low during working. |
|
Single acoustic signal | Drilling error (drilling drop-out): Yes! | |
124
|
|
A | AutoForce: Communication limited |
Maestro
–
since version 10.05
|
Press ESC to confirm | Number of expected and existing messages in CAN-BUS-System do not correspond. |
|
3 successive acoustic signals | Drilling error (drilling drop-out): No. | |
125
|
|
A | AutoForce: Communication errors |
Maestro
–
since version 10.05
|
Press ESC to confirm | Software on the Slave computer is incorrect. AutoForce functionality is not supported. |
|
3 successive acoustic signals | Drilling error (drilling drop-out): No. | |
126
|
|
A | AutoForce: Regulating deactivated |
Maestro
–
since version 10.05
|
Press ESC to confirm | All sensor values above valid range. |
|
3 successive acoustic signals | Drilling error (drilling drop-out): No. | |
127
|
|
W | AutoForce: Contact to ground interrupted |
Maestro
–
since version 10.06
|
Not possible until error has been rectified |
Only inadequate coulter pressure can be generated, resistance is too great. Measured forced on sensor is too low over a certain time period. Seed insertion depth cannot be retained. |
|
Single acoustic signal | Drilling error (drilling drop-out): Yes! | |
128
|
|
W | AutoForce: Sensor has plastic-type deformation |
Maestro
–
since version 10.05
|
Not possible until error has been rectified |
Sensor was plastically deformed. Original calibrated sensor value in unloaded status is not achieved again. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
129
|
|
A | Difference: Slave configured - slave identified |
Drill
–
since version 10.06
Maestro
–
since version 10.06
|
Press ESC to confirm | The number of configured Slaves differentiates from the number of identified Slaves. |
|
3 successive acoustic signals | Drilling error (drilling drop-out): Yes! | |
130
|
|
W | Minimum quantity |
Maestro
–
since version 10.06
|
Not possible until error has been rectified |
Row-individual flow monitoring. Too little material flow is detected for a specific row. |
|
Single acoustic signal | Drilling error (drilling drop-out): Yes! | |
131
|
|
W | More quantity |
Maestro
–
since version 10.06
|
Not possible until error has been rectified |
Row-individual flow monitoring. Fertiliser flow is detected although there should be no fertiliser flow in this row. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
132
|
|
W | Seed flow in deactivated half side |
Drill
–
since version 10.06
|
Not possible until error has been rectified | Material flow detected in the switched on half side. |
|
Single acoustic signal | Drilling error (drilling drop-out): Yes! | |
133
|
|
A | Seed control hardware configuration incompatible | Press ESC to confirm | The configuration of the built-in seed control module is not set correctly. |
|
3 successive acoustic signals | Drilling error (drilling drop-out): Yes! | ||
134
|
|
A | Partner Slave not present |
Drill
–
since version 10.06
Maestro
–
since version 10.06
|
Press ESC to confirm |
Is there is a combination of HORSCH front- and rear attachments connected together via the ISOBUS, functions one of the attachments as Master and one as Slave? The attachment which functions as Slave is not identified. |
|
3 successive acoustic signals | Drilling error (drilling drop-out): Yes! | |
135
|
|
W | Agtron fertiliser/seed flow monitoring interruption |
Drill
–
since version 10.07
|
Not possible until error has been rectified | Connection between two fertiliser/seed flow sensor interrupted. |
|
3 successive acoustic signals | Drilling error (drilling drop-out): No. | |
136
|
|
A | Agtron fertiliser/seed flow monitoring reset |
Drill
–
since version 10.07
|
Not possible until error has been rectified |
Communication to fertiliser/seed flow module temporarily interrupted. Module restarts. |
|
3 successive acoustic signals | Drilling error (drilling drop-out): No. | |
137
|
|
A | AutoLine: Tram line parameter change although automatic mode is active |
Drill
–
since version 10.09
Maestro
–
since version 10.09
|
Press ESC to confirm | Message appears when automatic tramline feature is still activated and the tram line settings shall still be modified. |
|
3 successive acoustic signals | Drilling error (drilling drop-out): No. | |
138
|
|
W | Row module: CAN bus error Bus 0 | Not possible until error has been rectified |
* Message only appears for individual modules:
=> Error source between upstream and notifying module.
=> Components possibly defective:
* Module
* Plug-and-socket connection
* Connecting cable
* Module addressing faulty
* Message appears for all modules:
* Module addressing faulty
|
|
Single acoustic signal | Drilling error (drilling drop-out): No. | ||
139
|
|
A | Row module: CAN bus fault Bus 0 |
Maestro
–
since version 10.07
|
Press ESC to confirm |
* Error source between the upstream module (left wing) or downstream module (right wing) and signalling module. Components possibly defective:
* Module
* Plug-and-socket connection
* Connecting cable
=> No communication to adjacent modules
|
|
3 successive acoustic signals | Drilling error (drilling drop-out): No. | |
140
|
|
W | Row module: Memory full CAN 0 | Overflow of receiving buffer of row module. |
|
Drilling error (drilling drop-out): No. | ||||
141
|
|
W | Row module: Memory full CAN 0 | Overflow of send buffer of row module. |
|
Drilling error (drilling drop-out): No. | ||||
142
|
|
A | Row module: Module RESET |
Maestro
–
since version 10.07
|
Press ESC to confirm | Unexpected restart of electronic processor in row module. |
|
Drilling error (drilling drop-out): Yes! | ||
143
|
|
A | Row module: Motor communication interrupted |
Maestro
–
since version 10.07
|
Press ESC to confirm |
Power voltage too low. Aborted update process. Faulty update. |
|
3 successive acoustic signals | Drilling error (drilling drop-out): Yes! | |
144
|
|
A | Row module: Motor controller RESET |
Maestro
–
since version 10.07
|
Press ESC to confirm |
Unexpected restart of power processor. Unexpected voltage drop. |
|
Drilling error (drilling drop-out): Yes! | ||
145
|
|
W | Row module: Motor controller Watchdog Reset |
Maestro
–
since version 10.07
|
Not possible until error has been rectified | Unexpected restart of electronic processor in row module. |
|
Single acoustic signal | Drilling error (drilling drop-out): Yes! | |
146
|
|
A | Row module: Metering motor not connected |
Maestro
–
since version 10.07
|
Press ESC to confirm |
The following was detected on system restart: Wiring to motor interrupted. |
|
3 successive acoustic signals | Drilling error (drilling drop-out): Yes! | |
147
|
|
W | Row module: Motor driver fault |
Maestro
–
since version 10.07
|
Not possible until error has been rectified |
* Possible causes:
* Temporary voltage drop
* Overheating
* Module defective
|
|
Single acoustic signal | Drilling error (drilling drop-out): Yes! | |
148
|
|
A | Row module: Motor overload |
Maestro
–
since version 10.07
|
Press ESC to confirm |
Current to motor too high through mechanical overload. Motor switches off. Drilling error! |
|
3 successive acoustic signals | Drilling error (drilling drop-out): Yes! | |
149
|
|
W | Row module: Power voltage too high |
Maestro
–
since version 10.07
|
Not possible until error has been rectified | Power voltage too high. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
150
|
|
W | Row module: Power voltage too low |
Maestro
–
since version 10.07
|
Not possible until error has been rectified | Power voltage too low. Motor speed limited. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
151
|
|
A | Row module: Power voltage critical. Motor stop |
Maestro
–
since version 10.07
|
Press ESC to confirm | Power voltage too high. Module still operational. |
|
3 successive acoustic signals | Drilling error (drilling drop-out): Yes! | |
152
|
|
W | Row module: Downpipe sensor supply voltage too high |
Maestro
–
since version 10.07
|
Not possible until error has been rectified |
Supply voltage too high. Module defective. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
153
|
|
W | Row module: Downpipe sensor supply voltage too low |
Maestro
–
since version 10.07
|
Not possible until error has been rectified |
Supply voltage too low. Module defective. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
154
|
|
W | Row module: Downpipe sensor current too high |
Maestro
–
since version 10.07
|
Not possible until error has been rectified |
Current on downpipe sensor too high. Short-circuit (cable damaged). Downpipe sensor defective. Module defective. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
155
|
|
W | Row module: Downpipe sensor current too low |
Maestro
–
since version 10.07
|
Not possible until error has been rectified |
Current on downpipe sensor too low. Cable break (cable damaged). Downpipe sensor defective. Module defective. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
156
|
|
W | Row module: Coulter pressure sensor supply voltage too high |
Maestro
–
since version 10.07
|
Not possible until error has been rectified |
Supply voltage on coulter pressure sensor too high. Measuring accuracy of coulter pressure sensor restricted. Module defective. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
157
|
|
W | Row module: Coulter pressure sensor supply voltage too low |
Maestro
–
since version 10.07
|
Not possible until error has been rectified |
Supply voltage on coulter pressure sensor too low. Measuring accuracy of coulter pressure sensor restricted. Module defective. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
158
|
|
W | Row module: Coulter pressure sensor current supply too high |
Maestro
–
since version 10.07
|
Not possible until error has been rectified |
Current on coulter pressure sensor too high. Short-circuit (cable damaged). Coulter pressure sensor defective. Module defective. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
159
|
|
W | Row module: Coulter pressure sensor current supply too low |
Maestro
–
since version 10.07
|
Not possible until error has been rectified |
Current on coulter pressure sensor too low. Cable break (cable damaged). Coulter pressure sensor defective. Module defective. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
160
|
|
W | Row module: Coulter pressure valve supply voltage too high |
Maestro
–
since version 10.07
|
Not possible until error has been rectified | Supply voltage on coulter pressure valve too high. Control accuracy of coulter pressure system restricted. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
161
|
|
W | Row module: Coulter pressure valve supply voltage too low |
Maestro
–
since version 10.07
|
Not possible until error has been rectified | Supply voltage on coulter pressure valve too low. Control accuracy of coulter pressure system restricted. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
162
|
|
W | Row module: Coulter pressure valve current too high |
Maestro
–
since version 10.07
|
Not possible until error has been rectified |
* Current on coulter pressure valve too high:
* Short-circuit (cable damaged).
* Coulter pressure valve defective.
* Module defective.
|
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
163
|
|
W | Row module: Coulter pressure valve current too low |
Maestro
–
since version 10.07
|
Not possible until error has been rectified |
* Current on coulter pressure valve too low:
* Cable break (cable damaged).
* Coulter pressure valve defective.
* Module defective.
|
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
164
|
|
W | Row module: Coulter pressure sensor signal current too high |
Maestro
–
since version 10.07
|
Not possible until error has been rectified | Current on the signal line of the coulter pressure sensor too high (>21 mA). |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
165
|
|
W | Row module: Coulter pressure sensor signal current too low |
Maestro
–
since version 10.07
|
Not possible until error has been rectified | Current on the signal line of the coulter pressure sensor too low (<3,5mA). |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
166
|
|
W | Row module: Fertiliser/seed flow sensor supply voltage too high |
Maestro
–
since version 10.07
|
Not possible until error has been rectified |
Supply voltage on fertiliser/seed flow sensor too high. Module defective. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
167
|
|
W | Row module: Fertiliser/seed flow sensor supply voltage too low |
Maestro
–
since version 10.07
|
Not possible until error has been rectified |
Supply voltage on fertiliser/seed flow sensor too low. Module defective. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
168
|
|
W | Row module: Fertiliser/seed flow sensor current too high |
Maestro
–
since version 10.07
|
Not possible until error has been rectified |
Current for fertiliser/seed flow sensor too high. Short-circuit (cable damaged). Fertiliser/seed flow sensor defective. Module defective. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
169
|
|
W | Row module: Fertiliser/seed flow sensor current too low |
Maestro
–
since version 10.07
|
Not possible until error has been rectified |
Current for fertiliser/seed flow sensor too low. Cable break (cable damaged). Fertiliser/seed flow sensor defective. Module defective. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
170
|
|
W | Row module: FRAM defective |
Maestro
–
since version 10.07
|
Not possible until error has been rectified | Memory in row module defective. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
171
|
|
W | Row module: FRAM data invalid |
Maestro
–
since version 10.07
|
Not possible until error has been rectified |
Data in FRAM memory of row module invalid/cannot be read. Data is reset to default. All module parameters were reset to factory settings. Occurrence is possible after update as long as connected to ServiceTool. Error must not be displayed anymore after restarting the machine. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
172
|
|
W | Row module: Acceleration sensor defective |
Maestro
–
since version 10.07
|
Not possible until error has been rectified |
Acceleration sensor in row module defective. Row module defective. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
173
|
|
W | Row module: Acceleration sensor data invalid |
Maestro
–
since version 10.07
|
Not possible until error has been rectified | Data of the accelerometer sensor in the row module invalid. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
174
|
|
W | Row module: Coulter pressure valve short-circuit |
Maestro
–
since version 10.07
|
Not possible until error has been rectified |
Current on coulter pressure valve much too high (shut-off by hardware). Short-circuit (cable damaged). Coulter pressure valve defective. Module defective. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
175
|
|
W | Row module: Electronics voltage too high |
Maestro
–
since version 10.07
|
Not possible until error has been rectified | Electronic voltage too high. Module still operational. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
176
|
|
W | Row module: Electronics voltage too low |
Maestro
–
since version 10.07
|
Not possible until error has been rectified | Electronics voltage too low. Module still operational. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
177
|
|
A | Row module: Electronics voltage critical |
Maestro
–
since version 10.07
|
Press ESC to confirm |
Electronics voltage too low or not available. Module no longer operable. Motor switches off. Drilling error! |
|
3 successive acoustic signals | Drilling error (drilling drop-out): Yes! | |
178
|
|
W | Row module: CAN communication duplicate addressing |
Maestro
–
since version 10.07
|
Not possible until error has been rectified | Addressing of modules invalid. |
|
Single acoustic signal | Drilling error (drilling drop-out): Yes! | |
179
|
|
A | Row module: Motor overload |
Maestro
–
since version 10.12
Maestro
–
Versions 10.07 to 10.11
|
Press ESC to confirm |
Excessive current consumption of motor for extended period. Motor temperature too high. Motor switches off. Drilling error! |
|
3 successive acoustic signals | Drilling error (drilling drop-out): Yes! | |
180
|
|
W | Row module: Downpipe sensor LIN bus not connected |
Maestro
–
since version 10.07
|
Not possible until error has been rectified | Communication system (LIN bus) to sensor is not connected. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
181
|
|
W | Row module: Downpipe sensor timeout |
Maestro
–
since version 10.07
|
Not possible until error has been rectified | No communication between row module and downpipe sensor. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
182
|
|
W | Row module: Downpipe sensor signal line defective |
Maestro
–
since version 10.07
|
Not possible until error has been rectified |
Check of signal line with test pulses not successful. Test of signal line by software takes place automatically when machine is not working. Cable break (cable damaged). |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
183
|
|
W | Row module: Downpipe sensor communication error |
Maestro
–
since version 10.07
|
Not possible until error has been rectified | Error when exchanging data of the downpipe sensor. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
184
|
|
W | Row module: Downpipe sensor sender light barrier defective |
Maestro
–
since version 10.07
|
Not possible until error has been rectified | Downpipe sensor defective. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
185
|
|
W | Row module: Downpipe sensor undervoltage |
Maestro
–
since version 10.07
|
Not possible until error has been rectified | Supply voltage on downpipe sensor too low. Metering accuracy affected. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
186
|
|
W | Row module: Downpipe sensor communication error |
Maestro
–
since version 10.07
|
Not possible until error has been rectified | Faulty messages are sent to the sensor (defective LIN frame). |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
187
|
|
W | Row module: Fertiliser/seed flow sensor signal current too high |
Maestro
–
since version 10.07
|
Not possible until error has been rectified |
Current for fertiliser/seed flow sensor too high. Short-circuit (cable damaged). Fertiliser/seed flow sensor defective. Module defective. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
188
|
|
W | Row module: Fertiliser/seed flow sensor signal current too low |
Maestro
–
since version 10.07
|
Not possible until error has been rectified |
Current for fertiliser/seed flow sensor too low. Cable break (cable damaged). Fertiliser/seed flow sensor defective. Module defective. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
189
|
|
W |
Row module: Fertiliser/seed flow sensor signal voltage 0-10 V range too high |
Maestro
–
since version 10.07
|
Not possible until error has been rectified |
Voltage of signal line on fertiliser/seed flow sensor in 0-10 V range too high. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
190
|
|
W |
Row module: Fertiliser/seed flow sensor signal voltage 0-10 V range too low |
Maestro
–
since version 10.07
|
Not possible until error has been rectified |
Voltage of signal line on fertiliser/seed flow sensor in 0-10 V voltage range too low. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
191
|
|
W | Row module: Fertiliser/seed flow sensor signal voltage 0-12 V too high |
Maestro
–
since version 10.07
|
Not possible until error has been rectified | Voltage of signal line on fertiliser/seed flow sensor in 0-12 V voltage range too high. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
192
|
|
W |
Row module: Fertiliser/seed flow sensor signal voltage 0-12 V too low |
Maestro
–
since version 10.07
|
Not possible until error has been rectified |
Voltage of signal line on fertiliser/seed flow sensor in 0-12V voltage range too low. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
193
|
|
W | Row module: Downpipe sensor short-circuit |
Maestro
–
since version 10.07
|
Not possible until error has been rectified |
Current to downpipe sensor much too high (shut-off by hardware). Short-circuit (cable damaged). |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
194
|
|
W | Row module: Coulter pressure sensor short-circuit |
Maestro
–
since version 10.07
|
Not possible until error has been rectified |
Current to coulter pressure sensor much too high (shut-off by hardware). Short-circuit (cable damaged). |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
195
|
|
W | Row module: Fertiliser/seed flow sensor short-circuit |
Maestro
–
since version 10.07
|
Not possible until error has been rectified |
Current to fertiliser/seed flow sensor much too high (shut-off by hardware). Short-circuit (cable damaged). |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
196
|
|
W | Row module: Coulter pressure valve short-circuit |
Maestro
–
since version 10.07
|
Not possible until error has been rectified |
Current to coulter pressure valve much too high (shut-off by hardware). Short-circuit (cable damaged). |
|
Single acoustic signal | Drilling error (drilling drop-out): No. | |
197
|
|
A | Row module: Motor current too high |
Maestro
–
since version 10.07
|
Press ESC to confirm |
Current to motor too high. Motor switches off. Drilling error! |
|
3 successive acoustic signals | Drilling error (drilling drop-out): Yes! | |
198
|
|
A | Row module: Motor overload |
Maestro
–
since version 10.07
|
Press ESC to confirm |
Torque of the motor too high for extended period. Motor switches off. |
|
3 successive acoustic signals | Drilling error (drilling drop-out): Yes! | |
199
|
|
A | Row module: Motor wire break |
Maestro
–
since version 10.07
|
Press ESC to confirm |
During a system restart, a motor was detected on this module at least once. No motor is now detected any longer on the row module output. => Wire break (cable damaged/loose). |
|
3 successive acoustic signals | Drilling error (drilling drop-out): Yes! | |
200
|
|
A | Row module: No power supply |
Maestro
–
since version 10.07
|
Press ESC to confirm |
No power supply present at row module. Fuse defective, Wire break or tractor supply too low. |
|
3 successive acoustic signals | Drilling error (drilling drop-out): Yes! | |
201
|
|
W | Row module: CAN bus error Bus 1 | Not possible until error has been rectified |
* Message only appears for individual modules:
=> Error source between upstream and notifying module.
=> Components possibly defective:
* Module
* Plug-and-socket connection
* Connecting cable
* Module addressing faulty
* Message appears for all modules:
* Module addressing faulty
|
|
Single acoustic signal | Drilling error (drilling drop-out): No. | ||
202
|
|
A | LINAK overcurrent |
Drill
–
since version 10.10
Drill
–
Versions 10.07 and 10.09
Maestro
–
since version 10.10
Maestro
–
Versions 10.07 and 10.09
|
Press ESC to confirm |
Overload of section control motor. It is shut off for protection. |
|
3 successive acoustic signals | Drilling error (drilling drop-out): Yes! | |
203
|
|
W | Seed flow in deactivated row |
Drill
–
since version 10.07
|
Machine type: Panther with active DoubleRowSpace Mode. Seed/fertiliser flow is indicated in the seed hoses of the tram line during operation. |
|
Drilling error (drilling drop-out): No. | |||
204
|
|
A | Row module: CAN bus fault Bus 1 |
Maestro
–
since version 10.07
|
Press ESC to confirm |
* Error source between the upstream module (right wing) or downstream module (left wing) and signalling module.
Components possibly defective:
* Module
* Plug-and-socket connection
* Connecting cable
=> No communication to adjacent modules.
|
|
3 successive acoustic signals | Drilling error (drilling drop-out): No. | |
205
|
|
W | Row module: Memory full CAN 1 | Overflow of receiving buffer of row module. |
|
Drilling error (drilling drop-out): No. | ||||
206
|
|
W | Row module: Memory full CAN 1 | Overflow of send buffer of row module. |
|
Drilling error (drilling drop-out): No. | ||||
207
|
|
A | Row Control Tower 1 clogged |
Drill
–
since version 10.09
|
5 sec. | Press ESC to confirm |
Row Control Tower 1 filled to the sensor => no or reduced placement. Drilling error! Working speed too fast at too many closed valves (too much seed / fertiliser per second). Usually occurs in Double Row Space mode. |
|
3 successive acoustic signals | Drilling error (drilling drop-out): Yes! |
208
|
|
A | Row Control Tower 2 clogged |
Drill
–
since version 10.09
|
5 sec. | Press ESC to confirm |
Row Control Tower 2 filled to the sensor => no or reduced placement. Drilling error! Working speed too fast at too many closed valves (too much seed / fertiliser per second). Usually occurs in Double Row Space mode. |
|
3 successive acoustic signals | Drilling error (drilling drop-out): Yes! |
210
|
|
W | WorkLight Pro: Wire break |
Drill
–
since version 10.09
Maestro
–
since version 10.09
|
0 sec. | not necessary | No headlight is detected on the module output. Cable break (cable damaged) |
|
Single acoustic signal | Drilling error (drilling drop-out): No. |
211
|
|
W | WorkLight Pro: Short-circuit |
Drill
–
since version 10.09
Maestro
–
since version 10.09
|
0 sec. | not necessary |
Current between Pins 1 and 2 on module output too high. Short-circuit (hardware shut-off) (Cable damaged) |
|
Single acoustic signal | Drilling error (drilling drop-out): No. |
212
|
|
W | WorkLight Pro: Electronics voltage too low |
Drill
–
since version 10.09
Maestro
–
since version 10.09
|
0 sec. | Not possible until error has been rectified | Electronics voltage too low. Module no longer operable. Headlight groups are switched off. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. |
213
|
|
W | WorkLight Pro: Electronics voltage too high |
Drill
–
since version 10.09
Maestro
–
since version 10.09
|
0 sec. | Not possible until error has been rectified |
Electronic voltage too high. Module no longer operable. Headlight groups are switched off. The headlights come on again once the voltage is again in the normal range. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. |
214
|
|
W | WorkLight Pro: Job computer timeout |
Drill
–
since version 10.09
Maestro
–
since version 10.09
|
0 sec. | not necessary | Job computer no longer responds to the WorkLight Pro module (Timeout). |
|
Single acoustic signal | Drilling error (drilling drop-out): No. |
215
|
|
W | WorkLight Pro: Parameters reset to default |
Drill
–
since version 10.09
Maestro
–
since version 10.09
|
0 sec. | not necessary | All parameters were set to default. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. |
217
|
|
W | WorkLight Pro: Power voltage too low |
Drill
–
since version 10.09
Maestro
–
since version 10.09
|
0 sec. | Not possible until error has been rectified | Power voltage too low. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. |
218
|
|
W | WorkLight Pro: Power voltage too high |
Drill
–
since version 10.09
Maestro
–
since version 10.09
|
0 sec. | Not possible until error has been rectified | Power voltage too high. Module no longer operable. Headlight groups are switched off. |
|
Single acoustic signal | Drilling error (drilling drop-out): No Information. |
219
|
|
W | WorkLight Pro: No electronics voltage |
Drill
–
since version 10.09
Maestro
–
since version 10.09
|
0 sec. | Not possible until error has been rectified |
No electronics voltage on WorkLight Pro module. All headlight groups were switched off. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. |
220
|
|
W | WorkLight Pro: Watchdog error |
Drill
–
since version 10.09
Maestro
–
since version 10.09
|
0 sec. | Not possible until error has been rectified | Internal software error |
|
Single acoustic signal | Drilling error (drilling drop-out): No. |
221
|
|
W | WorkLight Pro: Parameter limits |
Drill
–
since version 10.09
Maestro
–
since version 10.09
|
0 sec. | Not possible until error has been rectified | Parameter set outside permissible parameter limit. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. |
222
|
|
W | WorkLight Pro: Duplicate addressing |
Drill
–
since version 10.09
Maestro
–
since version 10.09
|
0 sec. | Not possible until error has been rectified | More than one WorkLight Pro module detected on the bus. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. |
223
|
|
W | WorkLight Pro: Loose connection |
Drill
–
since version 10.09
Maestro
–
since version 10.09
|
0 sec. | Not possible until error has been rectified |
Power supply to WorkLight Pro module temporarily interrupted. Headlights come on again when the power supply is available. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. |
224
|
|
W | WorkLight Pro: Error overflow |
Drill
–
since version 10.09
Maestro
–
since version 10.09
|
0 sec. | Not possible until error has been rectified | Not all error messages could be transmitted to the job computer. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. |
225
|
|
W | WorkLight Pro: Update error |
Drill
–
since version 10.09
Maestro
–
since version 10.09
|
0 sec. | Not possible until error has been rectified | Unable to save parameters correctly during updating. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. |
226
|
|
W | WorkLight Pro: CRC update error |
Drill
–
since version 10.09
Maestro
–
since version 10.09
|
0 sec. | Not possible until error has been rectified | Unable to save parameters correctly during updating. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. |
227
|
|
W | WorkLight Pro: Output current too high |
Drill
–
since version 10.09
Maestro
–
since version 10.09
|
0 sec. | Not possible until error has been rectified |
Current output on the indicated WorkLight Pro output too high for an extended period (>12.5 A). Affected output is disabled. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. |
228
|
|
W | WorkLight Pro: Total current too high |
Drill
–
since version 10.09
Maestro
–
since version 10.09
|
0 sec. | Not possible until error has been rectified |
Total current consumption of the WorkLight Pro too high for an extended period (>25 A). All headlight groups were switched off. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. |
229
|
|
A | AutoLine: Direction of travel does not match the tram line rhythm |
Drill
–
since version 10.09
|
0 sec. | Press ESC to confirm |
Travel against the actual direction of travel of the current track took place in automatic mode. The direction of travel is no longer corrected by disabling the automatic function. As a result, the tram lines are switched incorrectly after the next track change. |
|
3 successive acoustic signals | Drilling error (drilling drop-out): Yes! |
230
|
|
A | Coulter pressure computer failed |
Drill
–
since version 10.10
|
60 sec. | Press ESC to confirm | Connection to coulter pressure computer is interrupted. |
|
3 successive acoustic signals | Drilling error (drilling drop-out): No. |
231
|
|
W | Electrical coulter pressure small drill: sensor lowering line wire break |
Drill
–
since version 10.10
|
not possible until error has been rectified | The sensor provides a value lower than 2 mA. |
|
single acoustic signal | Drilling error (drilling drop-out): No. | |
232
|
|
W | Electrical coulter pressure small drill: sensor lowering line short-circuit |
Drill
–
since version 10.10
|
not possible until error has been rectified | The sensor provides a value larger than 22 mA. |
|
single acoustic signal | Drilling error (drilling drop-out): No. | |
233
|
|
A |
Liquid fertiliser hopper empty Pump protection active |
Drill
–
since version 10.10
Maestro
–
since version 10.10
|
5 sec. | Press ESC to confirm |
The liquid fertiliser hopper content is below the lower empty hopper alarm. Liquid fertiliser placement was stopped. |
|
3 successive acoustic signals | Drilling error (drilling drop-out): No. |
234
|
|
W |
Liquid fertiliser hopper empty Pump protection active |
Drill
–
since version 10.10
Maestro
–
since version 10.10
|
not possible until error has been rectified | The liquid fertiliser hopper content is below the lower empty hopper alarm. Liquid fertiliser placement was stopped. |
|
single acoustic signal | Drilling error (drilling drop-out): No. | |
235
|
|
W | Row module: motor load too high |
Maestro
–
since version 10.10
|
not possible until error has been rectified | Motor load to high over extended period. Motor does not switch off. |
|
single acoustic signal | Drilling error (drilling drop-out): No. | |
236
|
|
A | Row module: motor blocked |
Maestro
–
since version 10.10
|
Press ESC to confirm | Motor moves very sluggishly for a longer period or is blocked. |
|
3 successive acoustic signals | Drilling error (drilling drop-out): Yes! | |
237
|
|
W | Row module: minimum rotational speed has been reached |
Maestro
–
since version 10.10
|
not possible until error has been rectified | The advancing speed is too low for the target plant spacing that has been set. The metering motor is unable to maintain the demanded rotary speed. The nominal plant distance can thus not be maintained. |
|
single acoustic signal | Drilling error (drilling drop-out): No. | |
238
|
|
A | Half-width flap: high current increase check LINAK flap |
Drill
–
since version 10.11
Maestro
–
since version 10.11
|
0 sec. | Press ESC to confirm | Blockade of the half-width motor. It is shut off for protection. |
|
3 successive acoustic signals | Drilling error (drilling drop-out): Yes! |
239
|
|
A | LINAK position signal too high. Short circuit |
Drill
–
since version 10.11
Maestro
–
since version 10.11
|
5 sec. | Press ESC to confirm | Voltage of the position signal too high (>5,0V). Short circuit (cable damaged). |
|
3 successive acoustic signals | Drilling error (drilling drop-out): Yes! |
240
|
|
A | Startup Error | Press ESC to confirm | Error in the startup of the processors within the job computer |
|
single audible signal | Drilling error (drilling drop-out): Yes! | ||
241
|
|
A | Configuration not found | Press ESC to confirm | Internal software error. Two functions use the same pin. |
|
single audible signal | Drilling error (drilling drop-out): No Information. | ||
242
|
|
A | Duplicate use of IOs | Press ESC to confirm | Internal software error. Two functions use the same pin. |
|
single audible signal | Drilling error (drilling drop-out): Yes! | ||
243
|
|
A | Different software on slave computers | Press ESC to confirm |
Panther/Partner/RowControl/Drill M: Slave and master job computers cannot communicate correctly with each other as they have different software versions. |
|
single audible signal | Drilling error (drilling drop-out): Yes! | ||
244
|
|
A | Hardware initialisation fault | Press ESC to confirm | BasisLIB returns error when initialising the hardware; the function of at least one of the ports/pins cannot be ensured |
|
Single acoustic signal | Drilling error (drilling drop-out): Yes! | ||
245
|
|
A | Bus error CAN0 | Press ESC to confirm |
Partner configures as slave through additional hopper: IsoBus load or internal system load too high for flawless operation. |
|
single audible signal | Drilling error (drilling drop-out): Yes! | ||
246
|
|
A | Bus error CAN1 | Press ESC to confirm |
Panther/RowControl/Drill M machine types: SubBus load or internal system load too high for flawless operation. |
|
single audible signal | Drilling error (drilling drop-out): Yes! | ||
247
|
|
A | internal error | Press ESC to confirm |
* Internal software error. The additional number in the alarm indicates the exact error location of the software:
* 1 = Internal software error
* 2 = Internal software error
* 3 = Internal software error
* 4 = DDOP (device description) is rejected by the TaskController in the terminal
|
|
single audible signal | Drilling error (drilling drop-out): Yes! | ||
248
|
|
A | Basis Lib error | Press ESC to confirm |
* BasisLib error displayed on the terminal only in Beta software versions, e.g.:
* IO voltage check at startup
* Current checks
* e.g.: 0x1E8 - Voltage or current problem
* Additional hexadecimal code in the alarm indicates the exact error location of the software. This is required for a more exact analysis.
|
|
single acoustic signal | Drilling error (drilling drop-out): No. | ||
249
|
|
A | IsoBus defective or overloaded | Press ESC to confirm |
The internal buffer for IsoBus messages is overflowing (1000 messages could not be sent). The IsoBus is faulty or has a very high bus load (over 90%) over a longer period of time. This is why our job computer cannot send its messages for UT, TC and data logger. |
|
single audible signal | Drilling error (drilling drop-out): Yes! | ||
260
|
|
A | Half-width flap: LINAK position signal too low. Cable break |
Drill
–
since version 10.11
Maestro
–
since version 10.11
|
5 sec. | Press ESC to confirm | Voltage of the position signal too low (< 250mV). Cable break (cable damaged). |
|
3 successive acoustic signals | Drilling error (drilling drop-out): Yes! |
261
|
|
A | Check half-width flap |
Drill
–
since version 10.11
Maestro
–
since version 10.11
|
0 sec. | Press ESC to confirm | Occurs in case of a blockade of the half-width flap after having started the motor. |
|
3 successive acoustic signals | Drilling error (drilling drop-out): Yes! |
262
|
|
A | Row module: Communication to job computer interrupted |
Maestro
–
since version 10.12
|
0 sec. | Press ESC to confirm | Messages from the job computer do not arrive at the module for several seconds. |
|
3 successive acoustic signals | Drilling error (drilling drop-out): Yes! |
263
|
|
W | Row module: Sensor soiled |
Maestro
–
since version 10.14
Maestro
–
Versions 10.12 and 10.13
|
0 sec. | not possible until error has been rectified | Downpipe sensor of the indicated row signals very strong soiling. |
|
Single acoustic signal | Drilling error (drilling drop-out): No. |
264
|
|
A | Check of row addressing: Sequence not correct |
Maestro
–
since version 10.12
|
0 sec. | Confirm with checkmark button |
When checking row addressing, the correct number of configured rows was found The row modules are not connected in the addressed sequence. |
|
none | Drilling error (drilling drop-out): Yes! |
265
|
|
A | Checking row addressing: duplicate addressing |
Maestro
–
since version 10.12
|
0 sec. | Confirm with checkmark button |
When checking row addressing, the correct number of configured rows was found. At least two modules have the same address. |
|
none | Drilling error (drilling drop-out): Yes! |
266
|
|
A | Checking row addressing: not enough rows |
Maestro
–
since version 10.12
Maestro
–
since version 10.12
|
0 sec. | Confirm with cross, setting wrench or checkmark button | When checking row addressing it was detected that fewer rows are connected than have been configured. The number of configured rows is displayed next to the row symbol. |
|
none | Drilling error (drilling drop-out): Yes! |
267
|
|
A | Checking row addressing: faulty configuration |
Maestro
–
since version 10.12
Maestro
–
since version 10.12
|
0 sec. | Confirm with cross or setting wrench button | When checking row addressing it was detected that more rows are connected than have been configured. The number of configured rows is displayed next to the row symbol. |
|
none | Drilling error (drilling drop-out): Yes! |
268
|
|
W | Checking row addressing: Timeout |
Maestro
–
since version 10.12
|
0 sec. | not possible until error has been rectified | One or several row modules have not responded while checking row addressing. |
|
Single acoustic signal | Drilling error (drilling drop-out): Yes! |
269
|
|
W | Checking row addressing: Connection between job computer and first row interrupted |
Maestro
–
since version 10.12
|
0 sec. | not possible until error has been rectified | When checking row addressing it was detected that the connection between job computer and first connected row is interrupted. |
|
Single acoustic signal | Drilling error (drilling drop-out): Yes! |
270
|
|
W | Checking row addressing: Connection between job computer and two rows interrupted |
Maestro
–
since version 10.12
|
0 sec. | not possible until error has been rectified | When checking row addressing it was detected that the connection between the two indicated rows is interrupted. |
|
Single acoustic signal | Drilling error (drilling drop-out): Yes! |
271
|
|
W | Check the row addressing: Can Enable short-circuit |
Maestro
–
since version 10.12
|
0 sec. | not possible until error has been rectified | When checking the row addressing, it was detected that there is a short-circuit between Can Enable (PIN 5 on the 6-pin AMP connector) and the operating voltage in the row bus. |
|
single audible signal | Drilling error (drilling drop-out): Yes! |
272
|
|
A | Check the row addressing: Addressing not recommended |
Maestro
–
since version 10.12
|
0 sec. | confirm with checkmark or cross button | The row bus is checked for errors before manual row addressing is performed. Errors have been noted during this check. |
|
none | Drilling error (drilling drop-out): Yes! |
273
|
|
A | Foldingpoti wire break |
Drill
–
since version 10.13
Maestro
–
since version 10.13
|
Press ESC to confirm | While automatic folding (folding in/unfolding) is active, the wing potentiometer signals a value smaller than 2 mA. |
|
3 successive acoustic signals | Drilling error (drilling drop-out): No. | |
274
|
|
A | Wing potentiometer short-circuit |
Drill
–
since version 10.13
Maestro
–
since version 10.13
|
Press ESC to confirm | While automatic folding (folding in/unfolding) is active, the wing potentiometer signals a value greater than 22 mA. |
|
3 successive acoustic signals | Drilling error (drilling drop-out): No. | |
275
|
|
A | Rotary speed of the left drill shaft too low |
Maistro
–
since version 10.13
|
30 sec. | Press ESC to confirm | The speed of the left drill shaft is lower than the limit set in the configuration under rotary speed 1. |
|
3 successive acoustic signals | Drilling error (drilling drop-out): No. |
276
|
|
A | Rotary speed of the right drill shaft too low |
Maistro
–
since version 10.13
|
30 sec. | Press ESC to confirm | The speed of the right drill shaft is lower than the limit set in the configuration under rotary speed 2. |
|
3 successive acoustic signals | Drilling error (drilling drop-out): No. |
277
|
|
A | Rotary speed of the left drill shaft too low, deviation from the target value |
Maistro
–
since version 10.13
|
30 sec. | Press ESC to confirm |
Drill shaft monitoring is activated. The left drill shaft speed deviates more than the set limit (shaft speed in the configuration) from the calculated target speed (calculated by the speed/working width per row/target value and seeds per revolution). |
|
3 successive acoustic signals | Drilling error (drilling drop-out): Yes! |
278
|
|
A | Rotary speed of the right drill shaft too low, deviation from the target value |
Maistro
–
since version 10.13
|
30 sec. | Press ESC to confirm |
Drill shaft monitoring is activated. The right drill shaft speed deviates more than the set limit (shaft speed in the configuration) from the calculated target speed (calculated by the speed/working width per row/target value and seeds per revolution). |
|
3 successive acoustic signals | Drilling error (drilling drop-out): Yes! |
281
|
|
A | Wing potentiometer no work possible |
Drill
–
since version 10.13
Maestro
–
since version 10.13
|
30 sec. | Press ESC to confirm |
The wing potentiometer signals a value larger than 22 mA. The machine never has a working signal because of this high value. The machine can no longer drill. |
|
3 successive acoustic signals | Drilling error (drilling drop-out): Yes! |
282
|
|
W | Row module: statistics cannot be updated |
Maestro
–
since version 10.16
|
not possible until the error has been rectified |
If implausible grains are detected by the row sensor, then these are not used for the statistics (missed/double seeds and coefficient of variation). If the sensor reports implausible grains over a longer period of time (approx. 5 sec), the statistics cannot be recalculated (updated) and this error EC-282 is displayed. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
283
|
|
A | Master job computer: Power voltage too low |
Maistro
–
since version 10.17
Drill
–
since version 10.17
Maestro
–
since version 10.17
|
Press ESC to confirm |
* Too low a power voltage was measured at the input of the subscriber master.
* Malfunction of the master and subsequent slaves or modules possible, as the master power voltage is forwarded to other slaves and modules depending on the type of wiring:
* Valves for e.g. folding are not actuated or are actuated with too little voltage
* Metering motors are not activated or have too little power.
|
|
single audible signal | Drilling error (drilling drop-out): Yes! | |
284
|
|
A | Product/Tower Slave: Power voltage too low |
Drill
–
since version 10.17
|
Press ESC to confirm |
* Too low a power voltage was measured at the input of the slave.
Potential faulty behaviour of the slave:
* Product Slave: Metering motors are not activated or have too little power.
* Tower Slave: Row Control flaps are not selected.
|
|
3 successive acoustic signals | Drilling error (drilling drop-out): Yes! | |
285
|
|
W | Weighing module has failed |
Maestro
–
since version 10.18
|
not possible until the error has been rectified | Communication / supply to the weighing module is interrupted or module is defective. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
286
|
|
W | Weighing module: Communication faulty |
Maestro
–
since version 10.18
|
not possible until the error has been rectified | Communication / supply to the weighing module is interrupted or module is defective. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
287
|
|
W | Weighing module: Communication to job computer interrupted |
Maestro
–
since version 10.18
|
not possible until the error has been rectified | Communication / supply to the weighing module is interrupted or module is defective. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
288
|
|
W | Weighing module: Communication faulty |
Maestro
–
since version 10.18
|
not possible until the error has been rectified | Communication / supply to the weighing module is interrupted or module is defective. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
289
|
|
W | Weighing module: Data invalid |
Maestro
–
since version 10.18
|
not possible until the error has been rectified | Job computer sends invalid configuration for the LCEM / CAN fault. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
290
|
|
W | Weighing module: Data invalid |
Maestro
–
since version 10.18
|
not possible until the error has been rectified | Job computer sends invalid configuration for the LCEM / CAN fault. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
291
|
|
W | Weighing module: Data invalid |
Maestro
–
since version 10.18
|
not possible until the error has been rectified | Job computer sends invalid configuration for the LCEM / CAN fault. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
292
|
|
W | Weighing module: Watchdog error |
Maestro
–
since version 10.18
|
not possible until the error has been rectified | Unexpected restart of electronic processor in weighing module. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
293
|
|
W | Weighing module overheated |
Maestro
–
since version 10.18
|
not possible until the error has been rectified |
Weighing module has reached its temperature limit. Weighing module switches off automatically to avoid damage caused by overheating. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
294
|
|
W | Weighing module: Data invalid |
Maestro
–
since version 10.18
|
not possible until the error has been rectified | Weighing module defective |
|
single audible signal | Drilling error (drilling drop-out): No. | |
295
|
|
W | Weighing module: Power voltage too low |
Maestro
–
since version 10.18
|
not possible until the error has been rectified | Power voltage too low. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
296
|
|
W | Weighing module: internal measuring voltage too low |
Maestro
–
since version 10.18
|
not possible until the error has been rectified | Defect on weighing module. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
297
|
|
W | Weighing module: Measuring cell voltage too low |
Maestro
–
since version 10.18
|
not possible until the error has been rectified |
Defect on weighing module. Defect of a measuring cell. Measuring cell supply short-circuit. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
298
|
|
W | Weighing module: Measuring cell voltage too low |
Maestro
–
since version 10.18
|
not possible until the error has been rectified | Weighing module configured incorrectly or defective |
|
single audible signal | Drilling error (drilling drop-out): No. | |
299
|
|
W | Weighing module: Measuring cell voltage too low |
Maestro
–
since version 10.18
|
not possible until the error has been rectified | Weighing module configured incorrectly or defective |
|
single audible signal | Drilling error (drilling drop-out): No. | |
300
|
|
W | Weighing module: Power voltage too low |
Maestro
–
since version 10.18
|
not possible until the error has been rectified | Power voltage too low. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
301
|
|
W | Weighing module: internal measuring voltage too low |
Maestro
–
since version 10.18
|
not possible until the error has been rectified | Defect on weighing module. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
302
|
|
W | Weighing module: Measuring cell voltage too low |
Maestro
–
since version 10.18
|
not possible until the error has been rectified |
Defect on weighing module. Defect of a measuring cell. Measuring cell supply short-circuit. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
303
|
|
W | Weighing module: Measuring cell voltage too low |
Maestro
–
since version 10.18
|
not possible until the error has been rectified | Weighing module configured incorrectly or defective |
|
single audible signal | Drilling error (drilling drop-out): No. | |
304
|
|
W | Weighing module: Measuring cell voltage too low |
Maestro
–
since version 10.18
|
not possible until the error has been rectified | Weighing module configured incorrectly or defective |
|
single audible signal | Drilling error (drilling drop-out): No. | |
305
|
|
W | Weighing module: Power voltage too high |
Maestro
–
since version 10.18
|
not possible until the error has been rectified | Power voltage too high. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
306
|
|
W | Weighing module: internal measuring voltage too high |
Maestro
–
since version 10.18
|
not possible until the error has been rectified |
Faulty configuration. Defective weighing module. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
307
|
|
W | Weighing module: Measuring cell voltage too high |
Maestro
–
since version 10.18
|
not possible until the error has been rectified |
Faulty configuration. Defective weighing module. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
308
|
|
W | Weighing module: Measuring cell voltage too high |
Maestro
–
since version 10.18
|
not possible until the error has been rectified | Weighing module configured incorrectly or defective |
|
single audible signal | Drilling error (drilling drop-out): No. | |
309
|
|
W | Weighing module: Measuring cell voltage too high |
Maestro
–
since version 10.18
|
not possible until the error has been rectified | Weighing module configured incorrectly or defective |
|
single audible signal | Drilling error (drilling drop-out): No. | |
310
|
|
W | Weighing module: Power voltage too high |
Maestro
–
since version 10.18
|
not possible until the error has been rectified | Power voltage too high. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
311
|
|
W | Weighing module: internal measuring voltage too high |
Maestro
–
since version 10.18
|
not possible until the error has been rectified |
Faulty configuration. Defective weighing module. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
312
|
|
W | Weighing module: Measuring cell voltage too high |
Maestro
–
since version 10.18
|
not possible until the error has been rectified |
Faulty configuration. Defective weighing module. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
313
|
|
W | Weighing module: Measuring cell voltage too high |
Maestro
–
since version 10.18
|
not possible until the error has been rectified | Weighing module configured incorrectly or defective |
|
single audible signal | Drilling error (drilling drop-out): No. | |
314
|
|
W | Weighing module: Measuring cell voltage too high |
Maestro
–
since version 10.18
|
not possible until the error has been rectified | Weighing module configured incorrectly or defective |
|
single audible signal | Drilling error (drilling drop-out): No. | |
315
|
|
W | Weighing module: CAN BUS error |
Maestro
–
since version 10.18
|
not possible until the error has been rectified | Communication between LCEM and the connected components on the CAN BUS is impaired. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
316
|
|
W | Weighing module: CAN BUS error |
Maestro
–
since version 10.18
|
not possible until the error has been rectified | Communication between LCEM and the connected components on the CAN BUS is impaired. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
317
|
|
W | Weighing module: CAN BUS error |
Maestro
–
since version 10.18
|
not possible until the error has been rectified |
Communication between LCEM and the connected components on the CAN BUS is significantly impaired. Module switches off CAN connection. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
318
|
|
W | Weighing module: CAN memory full |
Maestro
–
since version 10.18
|
not possible until the error has been rectified | Overflow of receiving buffer of weighing module. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
319
|
|
W | Weighing module: CAN memory full |
Maestro
–
since version 10.18
|
not possible until the error has been rectified | Overflow of send buffer of weighing module. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
320
|
|
W | Weighing module: CAN communication duplicate addressing |
Maestro
–
since version 10.18
|
not possible until the error has been rectified | Addressing of modules invalid. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
321
|
|
W | Weighing module: Measuring cell current too low |
Maestro
–
since version 10.18
|
not possible until the error has been rectified |
Load cell defective. Wiring of load cell defective. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
322
|
|
W | Weighing module: Measuring cell current too low |
Maestro
–
since version 10.18
|
not possible until the error has been rectified | Weighing module configured incorrectly or defective |
|
single audible signal | Drilling error (drilling drop-out): No. | |
323
|
|
W | Weighing module: Measuring cell current too low |
Maestro
–
since version 10.18
|
not possible until the error has been rectified | Weighing module configured incorrectly or defective |
|
single audible signal | Drilling error (drilling drop-out): No. | |
324
|
|
W | Weighing module: Measuring cell current too high |
Maestro
–
since version 10.18
|
not possible until the error has been rectified |
Load cell defective. Wiring of load cell defective. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
325
|
|
W | Weighing module: Measuring cell current too high |
Maestro
–
since version 10.18
|
not possible until the error has been rectified | Weighing module configured incorrectly or defective |
|
single audible signal | Drilling error (drilling drop-out): No. | |
326
|
|
W | Weighing module: Measuring cell current too high |
Maestro
–
since version 10.18
|
not possible until the error has been rectified | Weighing module configured incorrectly or defective |
|
single audible signal | Drilling error (drilling drop-out): No. | |
327
|
|
W | Weighing module: Measuring cell current too low |
Maestro
–
since version 10.18
|
not possible until the error has been rectified |
Load cell defective. Wiring of load cell defective. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
328
|
|
W | Weighing module: Measuring cell current too low |
Maestro
–
since version 10.18
|
not possible until the error has been rectified | Weighing module configured incorrectly or defective |
|
single audible signal | Drilling error (drilling drop-out): No. | |
329
|
|
W | Weighing module: Measuring cell current too low |
Maestro
–
since version 10.18
|
not possible until the error has been rectified | Weighing module configured incorrectly or defective |
|
single audible signal | Drilling error (drilling drop-out): No. | |
330
|
|
W | Weighing module: Measuring cell current too high |
Maestro
–
since version 10.18
|
not possible until the error has been rectified |
Load cell defective. Wiring of load cell defective. |
|
single audible signal | Drilling error (drilling drop-out): No. | |
331
|
|
W | Weighing module: Measuring cell current too high |
Maestro
–
since version 10.18
|
not possible until the error has been rectified | Weighing module configured incorrectly or defective |
|
single audible signal | Drilling error (drilling drop-out): No. | |
332
|
|
W | Weighing module: Measuring cell current too high |
Maestro
–
since version 10.18
|
not possible until the error has been rectified | Weighing module configured incorrectly or defective |
|
single audible signal | Drilling error (drilling drop-out): No. | |
333
|
|
A | AutoLine: Settings TC incompatible! |
Maistro
–
since version 10.18
Drill
–
since version 10.18
Maestro
–
since version 10.18
|
Press ESC to confirm |
The connected terminal cannot support the current Tramline/AutoLine settings as it only reports Tramline Control Level 1. => A tramlines rhythm with half a working width at the start of the field must not be set. This would be a function of Tramline Control Level 2. |
|
3 successive acoustic signals | Drilling error (drilling drop-out): Yes! | |
334
|
|
A |
AutoLine: Settings Machine incompatible! |
Maistro
–
since version 10.18
Drill
–
since version 10.18
Maestro
–
since version 10.18
|
press ESC to confirm | Error occurs if no tramlines are switched over the entire rhythm length or if the softkey for activating the tramlines is deactivated. |
|
3 successive acoustic signals | Drilling error (drilling drop-out): Yes! |